Waterflow ECO Drip Tubing
WATERFLOW ECO
- Tru17mm diameter tubing with pressure compensating (PC) emitter
- Constant performance in all climates
- Patented Geoshield® antimicrobial lining prevents biofilm build-up inside tubing
- Optimal for use on severe slopes and long runs
- Provides maximum water distribution uniformity in tough topographical areas
- High-quality resins assure durable performance and long life
- Warranty against defects in materials or workmanship
- Silicon dripper diaphragm provides advanced chemical resistance
-
Recommended filtration: 120 Mesh for 0.4 GPH, 0.6 GPH, and 1.0 GPH
|
Part Number |
G-WFPC-17-1.6-24-ECO |
G-WFPC-17-2-24-ECO |
G-WFPC-17-4-24-ECO |
|
Emitter type |
PC |
PC |
PC |
|
Emitter spacing, in |
24 |
24 |
24 |
|
Emitter flow rate, nominal GPH |
0.4 |
0.6 |
1.0 |
|
Coil length, ft |
500 |
500 |
500 |
|
Parameter |
Specification |
|
Antimicrobial lining |
Yes |
|
Tubing diameter, nominal |
17 mm |
|
Wall thickness, nominal |
1.27 mm |
|
Emitter style |
Flat |
|
Pressure, min |
7 psi |
|
Pressure, max |
60 psi |
|
Pressure range, optimal |
20 to 50 psi |
|
Tubing warranty |
20 years |
Maximum length of a lateral flushing at 0.5 fps
0.4 gpm per lateral required to achieve 0.5 fps
|
Inlet Pressure |
Emitter Flow Rate, 12" Spacing |
Emitter Flow Rate, 24" Spacing |
||||
|
PSI |
0.4 GPH |
0.6 GPH |
1.0 GPH |
0.4 GPH |
0.6 GPH |
1.0 GPH |
|
10 |
156' |
134' |
95' |
264' |
228' |
162' |
|
20 |
291' |
247' |
171' |
504' |
430' |
198' |
|
30 |
364' |
309' |
213' |
636' |
540' |
374' |
|
40 |
419' |
354' |
243' |
734' |
622' |
428' |
|
50 |
464' |
392' |
268' |
814' |
688' |
474' |
|
60 |
502' |
424' |
290' |
882' |
746' |
512' |
Maximum length of a lateral flushing at 1 fps
0.8 gpm per lateral required to achieve 1 fps
|
Inlet Pressure |
Emitter Flow Rate, 12" Spacing |
Emitter Flow Rate, 24" Spacing |
||||
|
PSI |
0.4 GPH |
0.6 GPH |
1.0 GPH |
0.4 GPH |
0.6 GPH |
1.0 GPH |
|
10 |
111' |
99' |
74' |
178' |
160' |
214' |
|
20 |
241' |
208' |
149' |
406' |
354' |
256' |
|
30 |
314' |
270' |
191' |
536' |
462' |
330' |
|
40 |
368' |
315' |
222' |
632' |
544' |
386' |
|
50 |
412' |
352' |
247' |
712' |
610' |
430' |
|
60 |
450' |
384' |
268' |
780' |
668' |
458' |
Maximum length of a lateral flushing at 1.5 fps
1.2 gpm per lateral required to achieve 1.5 fps
|
Inlet Pressure |
Emitter Flow Rate, 12" Spacing |
Emitter Flow Rate, 24" Spacing |
||||
|
PSI |
0.4 GPH |
0.6 GPH |
1.0 GPH |
0.4 GPH |
0.6 GPH |
1.0 GPH |
|
10 |
78' |
71' |
58' |
118' |
110' |
90' |
|
20 |
197' |
173' |
129' |
320' |
286' |
216' |
|
30 |
266' |
233' |
170' |
444' |
390' |
290' |
|
40 |
320' |
278' |
200' |
538' |
470' |
344' |
|
50 |
363' |
314' |
225' |
616' |
536' |
388' |
|
60 |
401' |
346' |
246' |
682' |
592' |
426' |
Maximum length of a lateral flushing at 2 fps
1.6 gpm per lateral required to achieve 2 fps
|
Inlet Pressure |
Emitter Flow Rate, 12" Spacing |
Emitter Flow Rate, 24" Spacing |
||||
|
PSI |
0.4 GPH |
0.6 GPH |
1.0 GPH |
0.4 GPH |
0.6 GPH |
1.0 GPH |
|
10 |
54' |
51' |
43' |
80' |
76' |
66' |
|
20 |
158' |
143' |
111' |
252' |
228' |
182' |
|
30 |
224' |
199' |
150' |
364' |
328' |
252' |
|
40 |
275' |
243' |
180' |
454' |
404' |
304' |
|
50 |
317' |
278' |
205' |
528' |
466' |
348' |
|
60 |
354' |
309' |
226' |
592' |
522' |
386' |
Note: Emitter nominal flow rate @ 30psi = .42 GPH, .55 GPH, and 1.0 GPH