The Alderon Check-It™ Duplex Control Panel is designed to control and monitor a pump station with two submersible pumps in demand dose applications. It features an automatic alternating relay that balances pump run times each cycle, supports up to five float switch inputs for advanced level monitoring, and includes Alderon’s one-touch self-diagnostic system. The heavy-duty NEMA 4X enclosure, IEC motor contactors, and built-in dry contacts make it a complete, field-ready solution for duplex lift stations and pump chambers.

ELECTRICAL SPECIFICATIONS

Voltage

120/230 VAC, Single Phase

Full Load Amps (FLA)

0–20 FLA per pump

Frequency

60 Hz

Pump Power Input

120/230 VAC

Alarm/Control Circuit

120 VAC

Motor Contactors

IEC-rated, 2,000,000 cycle rating (one per pump)

Circuit Protection

Motor circuit breaker per pump + 3 Amp auto-reset control fuse

PHYSICAL SPECIFICATIONS

Enclosure Type

NEMA 4X thermoplastic — indoor/outdoor rated

Dimensions

12.75″ W × 16.00″ H × 7.50″ D

Listing

UL 508A Listed

Country of Origin

Made in USA

Warranty

3 Years

FLOAT SWITCH INPUTS

Standard Floats Included

3 mechanical float switches with 20 ft cords

Standard Float Functions

OFF (Pump Stop), LEAD ON (Lead Pump Start), ALARM (High Water)

Maximum Float Inputs

5 floats supported

Extended Float Functions

Low Alarm / Redundant Off, Lead On, Lag On / High, High Level Alert

Float Cord Length

20 ft

CONTROLS & INDICATORS

Check-It™ Self-Diagnosing System: One-touch troubleshooting for both pump circuits

Multi-Color LED Beacon: Green = Normal | Flashing Green = Pump Running | Flashing Red = High/Low Alarm

Alternating Relay: Automatically alternates lead pump each cycle for equal wear

Pump HAND / OFF / AUTO Toggle Switch: One per pump

Pump Run Indicator Light: One per pump

Alarm Toggle Switch: Run / Test / Mute

Audible Alarm Buzzer: 100 dB high-decibel alert

Dry Contacts: NO/NC alarm and power loss contacts + NO/NC pump run contacts (per pump)

Color-coded wiring with field wiring terminal strips

TYPICAL APPLICATIONS

Duplex demand dose septic pump chambers (two-pump stations)

Residential and light-commercial duplex lift stations

Redundant pump systems where lead/lag operation is required

Applications requiring automatic pump alternation for equal service life

Any two-pump submersible installation requiring alternating control and high water alarm

CERTIFICATIONS & COMPLIANCE

Safety Listing

UL 508A (Industrial Control Panels)

Enclosure Rating

NEMA 4X (Indoor/Outdoor)

Country of Manufacture

Made in USA