Coiled black irrigation tube with a label on a white background

Waterflow Pro Drip Tubing

G-WFCL- 16-4-24
$475.00 USD
Sale price  $475.00 USD Regular price 
Skip to product information
Coiled black irrigation tube with a label on a white background

Waterflow Pro Drip Tubing

$475.00 USD
Sale price  $475.00 USD Regular price 
Shipping calculated at checkout.

Why Choose WaterflowPRO?

  • 16mm diameter tubing with PC or Classic emitter
  • Patented nano-Rootguard® band PROtects against root intrusion
  • Patented Geoshield® antimicrobial lining prevents biofilm build-up inside tubing
  • Constant performance in all climates
  • Optimal for use on severe slopes and long runs
  • Provides maximum water distribution uniformity in tough topographical areas
  • High quality resins assure durable performance and long life
  • Warranty against defects in materials or workmanship
  • Emitter spacing available in 12" or 24"

Part Number

G-WFCL- 16-4-24

G-WFPC- 16-2-12

G-WFPC- 16-4-12

G-WFPC- 16-2-24

G-WFPC- 16-4-24

Emitter type

Classic

PC

PC

PC

PC

Emitter spacing, in

24

12

12

24

24

Emitter flow rate, nominal GPH

1.3 @ 20 psi

0.6

0.9

0.6

0.9

Coil length, ft

500

500

500

500

500

 

Parameter

Specification

Prevents root intrusion

Yes

Antimicrobial lining

Yes

Tubing diameter, nominal

16 mm

Wall thickness, nominal

1.10 mm

Emitter style

Cylindrical

Pressure, min

7 psi

Pressure, max

60 psi

Pressure range, optimal

20 to 50 psi

Tubing warranty

20 years

Rootguard warranty

10 years

Maximum length of a lateral flushing at 2 fps

1.48 gpm per lateral required to achieve 2 fps

Inlet Pressure

PC Emitter Flow Rate, 12" Spacing

PC Emitter Flow Rate, 24" Spacing

PSI

0.6 GPH

0.9 GPH

0.6 GPH

0.9 GPH

10

32'

30'

54'

52'

20

98'

84'

170'

170'

30

141'

118'

248'

248'

40

176'

144'

310'

312'

50

205'

166'

364'

364'

60

230'

183'

410'

410'

 

Maximum length of a lateral flushing at 1.5 fps

1.11 gpm per lateral required to achieve 1.5 fps

Inlet Pressure

PC Emitter Flow Rate, 12" Spacing

PC Emitter Flow Rate, 24" Spacing

PSI

0.6 GPH

0.9 GPH

0.6 GPH

0.9 GPH

10

47'

42'

80'

72'

20

125'

103'

220'

182'

30

172'

139'

306'

250'

40

208'

166'

374'

300'

50

238'

188'

430'

342'

60

264'

208'

478'

378'

 

Maximum length of a lateral flushing at 1 fps

0.74 gpm per lateral required to achieve 1 fps

Inlet Pressure

PC Emitter Flow Rate, 12" Spacing

PC Emitter Flow Rate, 24" Spacing

PSI

0.6 GPH

0.9 GPH

0.6 GPH

0.9 GPH

10

70'

59'

122'

102'

20

157'

125'

280'

226'

30

207'

162'

374'

294'

40

244'

190'

444'

346'

50

275'

212'

502'

388'

60

302'

232'

552'

426'

 

Maximum length of a lateral flushing at 0.5 fps

0.37 gpm per lateral required to achieve 0.5 fps

Inlet Pressure

PC Emitter Flow Rate, 12" Spacing

PC Emitter Flow Rate, 24" Spacing

PSI

0.6 GPH

0.9 GPH

0.6 GPH

0.9 GPH

10

102'

81'

182'

144'

20

193'

149'

352'

272'

30

244'

186'

448'

344'

40

283'

214'

520'

396'

50

315'

237'

580'

438'

60

342'

257'

630'

476'

 